Ventilation for control of the work environment /

"Designed to be used with the ACGIH Industrial Ventilation manual, Ventilation for Control of the Work Environment explains the rationale of the material contained in the manual while demonstrating both the theoretical and practical aspects of the subject. The design of local exhaust ventilatio...

Full description

Saved in:
Bibliographic Details
Main Author: Burgess, William A., 1924-
Other Authors: Ellenbecker, Michael J., Treitman, Robert D.
Format: Book
Language:English
Published: Hoboken, N.J. ; [Great Britain] : Wiley-Interscience, c2004.
Edition:2nd ed.
Subjects:
LEADER 02844cam a2200457 a 4500
001 c000404748
003 CARM
005 20190507113637.0
008 190507s2004 njua b 001 0 eng
010 |a 2004006447 
015 |a GBA3Y8292  |2 bnb 
016 7 |a 011613334  |2 Uk 
019 1 |a 25420911  |5 LACONCORD2021 
020 |a 047109532X (cased) :  |c £74.50 
035 |a (OCoLC)54817288  |5 LACONCORD2021 
040 |a StDuBDS  |d Uk  |b eng 
042 |a ukblsr 
050 0 0 |a TH7684.F2  |b .B86 2004 
082 0 0 |a 697.92  |2 22 
100 1 |a Burgess, William A.,  |d 1924- 
245 1 0 |a Ventilation for control of the work environment /  |c William A. Burgess, Michael J. Ellenbecker, Robert D. Treitman. 
250 |a 2nd ed. 
264 1 |a Hoboken, N.J. ;  |a [Great Britain] :  |b Wiley-Interscience,  |c c2004. 
300 |a xvi, 424 pages :  |b illustrations ;  |c 25 cm. 
336 |a text  |b txt  |2 rdacontent 
337 |a unmediated  |b n  |2 rdamedia 
338 |a volume  |b nc  |2 rdacarrier 
500 |a Formerly CIP.  |5 Uk 
504 |a Includes bibliographical references and index. 
505 0 |a 1. Ventilation for control -- 2. Principles of airflow -- 3. Airflow measurement techniques -- 4. General exhaust ventilation -- 5. Hood design -- 6. Hood designs for specific applications -- 7. Chemical laboratory ventilation -- 8. Design of single-hood systems -- 9. Design of multiple-hood systems -- 10. Fans and blowers -- 11. Air-cleaning devices -- 12. Replacement-air systems -- 13. Quantification of hood performance -- 14. Application of computational fluid dynamics to ventilation system design -- 15. Reentry. 
520 1 |a "Designed to be used with the ACGIH Industrial Ventilation manual, Ventilation for Control of the Work Environment explains the rationale of the material contained in the manual while demonstrating both the theoretical and practical aspects of the subject. The design of local exhaust ventilation systems is illustrated by examples taken from the authors' industrial experience. In addition, end-of-chapter problem sets are now presented to reinforce the content of appropriate chapters. Both English and metric units are used in this new edition, and new ventilation practices and research advances are noted throughout this major revision."--BOOK JACKET. 
650 0 |a Factories  |x Heating and ventilation. 
650 0 |a Industrial hygiene. 
700 1 |a Ellenbecker, Michael J. 
700 1 |a Treitman, Robert D. 
852 8 |b CARM  |i C13773  |p 0655395  |f BK 
852 8 |b SCAN  |h A3:AP05E0  |i C13773  |p 0655395  |f BK 
852 8 |b SCAN  |h A3:AP05E0  |i C13773  |p 0655395  |f BK 
999 f f |i d0b42883-738a-52f9-80df-8553356ba088  |s 698ee61a-efae-5ba3-8b08-853d69a42b05 
952 f f |p Can circulate  |a CAVAL  |b CAVAL  |c CAVAL  |d CARM 1 Store  |e C13773  |h Other scheme  |i book  |m 0655395 
952 f f |a CAVAL  |b CAVAL  |c CAVAL  |d Unmapped Location  |e C13773  |f A3:AP05E0  |h Other scheme