Ventilation for control of the work environment /
"Designed to be used with the ACGIH Industrial Ventilation manual, Ventilation for Control of the Work Environment explains the rationale of the material contained in the manual while demonstrating both the theoretical and practical aspects of the subject. The design of local exhaust ventilatio...
Saved in:
| Main Author: | |
|---|---|
| Other Authors: | , |
| Format: | Book |
| Language: | English |
| Published: |
Hoboken, N.J. ; [Great Britain] :
Wiley-Interscience,
c2004.
|
| Edition: | 2nd ed. |
| Subjects: |
| LEADER | 02844cam a2200457 a 4500 | ||
|---|---|---|---|
| 001 | c000404748 | ||
| 003 | CARM | ||
| 005 | 20190507113637.0 | ||
| 008 | 190507s2004 njua b 001 0 eng | ||
| 010 | |a 2004006447 | ||
| 015 | |a GBA3Y8292 |2 bnb | ||
| 016 | 7 | |a 011613334 |2 Uk | |
| 019 | 1 | |a 25420911 |5 LACONCORD2021 | |
| 020 | |a 047109532X (cased) : |c £74.50 | ||
| 035 | |a (OCoLC)54817288 |5 LACONCORD2021 | ||
| 040 | |a StDuBDS |d Uk |b eng | ||
| 042 | |a ukblsr | ||
| 050 | 0 | 0 | |a TH7684.F2 |b .B86 2004 |
| 082 | 0 | 0 | |a 697.92 |2 22 |
| 100 | 1 | |a Burgess, William A., |d 1924- | |
| 245 | 1 | 0 | |a Ventilation for control of the work environment / |c William A. Burgess, Michael J. Ellenbecker, Robert D. Treitman. |
| 250 | |a 2nd ed. | ||
| 264 | 1 | |a Hoboken, N.J. ; |a [Great Britain] : |b Wiley-Interscience, |c c2004. | |
| 300 | |a xvi, 424 pages : |b illustrations ; |c 25 cm. | ||
| 336 | |a text |b txt |2 rdacontent | ||
| 337 | |a unmediated |b n |2 rdamedia | ||
| 338 | |a volume |b nc |2 rdacarrier | ||
| 500 | |a Formerly CIP. |5 Uk | ||
| 504 | |a Includes bibliographical references and index. | ||
| 505 | 0 | |a 1. Ventilation for control -- 2. Principles of airflow -- 3. Airflow measurement techniques -- 4. General exhaust ventilation -- 5. Hood design -- 6. Hood designs for specific applications -- 7. Chemical laboratory ventilation -- 8. Design of single-hood systems -- 9. Design of multiple-hood systems -- 10. Fans and blowers -- 11. Air-cleaning devices -- 12. Replacement-air systems -- 13. Quantification of hood performance -- 14. Application of computational fluid dynamics to ventilation system design -- 15. Reentry. | |
| 520 | 1 | |a "Designed to be used with the ACGIH Industrial Ventilation manual, Ventilation for Control of the Work Environment explains the rationale of the material contained in the manual while demonstrating both the theoretical and practical aspects of the subject. The design of local exhaust ventilation systems is illustrated by examples taken from the authors' industrial experience. In addition, end-of-chapter problem sets are now presented to reinforce the content of appropriate chapters. Both English and metric units are used in this new edition, and new ventilation practices and research advances are noted throughout this major revision."--BOOK JACKET. | |
| 650 | 0 | |a Factories |x Heating and ventilation. | |
| 650 | 0 | |a Industrial hygiene. | |
| 700 | 1 | |a Ellenbecker, Michael J. | |
| 700 | 1 | |a Treitman, Robert D. | |
| 852 | 8 | |b CARM |i C13773 |p 0655395 |f BK | |
| 852 | 8 | |b SCAN |h A3:AP05E0 |i C13773 |p 0655395 |f BK | |
| 852 | 8 | |b SCAN |h A3:AP05E0 |i C13773 |p 0655395 |f BK | |
| 999 | f | f | |i d0b42883-738a-52f9-80df-8553356ba088 |s 698ee61a-efae-5ba3-8b08-853d69a42b05 |
| 952 | f | f | |p Can circulate |a CAVAL |b CAVAL |c CAVAL |d CARM 1 Store |e C13773 |h Other scheme |i book |m 0655395 |
| 952 | f | f | |a CAVAL |b CAVAL |c CAVAL |d Unmapped Location |e C13773 |f A3:AP05E0 |h Other scheme |