Guidelines for ventilation requirements in buildings /
These Guidelines recommend the ventilation required to obtain a desired indoor air quality in a space. The first step is to decide the air quality aimed for in the ventilated space. A certain air quality is prescribed to avoid adverse health effects while a decision is required on the level of perce...
Сохранить в:
| Корпоративные авторы: | , |
|---|---|
| Другие авторы: | |
| Формат: | |
| Язык: | English |
| Опубликовано: |
Luxembourg :
Commission of the European Communities,
1992.
|
| Серии: | Environment and quality of life ;
no. 11. EUR (Series) ; 14449 EN. |
| Предметы: |
| LEADER | 03053cam a2200421 a 4500 | ||
|---|---|---|---|
| 001 | c000406764 | ||
| 003 | CARM | ||
| 005 | 20201013171458.0 | ||
| 008 | 201013s1992 lu 000 0 eng d | ||
| 019 | 1 | |a 10101538 |z 46316645 |5 LACONCORD2021 | |
| 035 | |a (OCoLC)221428991 |5 LACONCORD2021 | ||
| 040 | |a WMDU |b eng |c WMDU | ||
| 082 | 0 | 4 | |a 363.7392 |2 20 |
| 245 | 0 | 0 | |a Guidelines for ventilation requirements in buildings / |c prepared by Working Group 6, Dominique Bienfait ... [et al.] ; reviewed and approved by the Concertation Committee. |
| 260 | |a Luxembourg : |b Commission of the European Communities, |c 1992. | ||
| 300 | |a 36 p. ; |c 30 cm. | ||
| 490 | 1 | |a Report ; |v No. 11 | |
| 490 | 1 | |a EUR ; |v 14449 EN | |
| 500 | |a At head of title: European Concerted Action "Indoor Air Quality & Its Impact On Man" (formerly COST Project 613") | ||
| 500 | |a "Commission for the European Communities, Directorate General for Science, Research and Development, Joint Research Centre - Environment Institute" --T.p. | ||
| 504 | |a Includes bibliographical references. | ||
| 520 | 3 | |a These Guidelines recommend the ventilation required to obtain a desired indoor air quality in a space. The first step is to decide the air quality aimed for in the ventilated space. A certain air quality is prescribed to avoid adverse health effects while a decision is required on the level of perceived air quality aimed for in the ventilated space. Three different comfort levels are suggested. The next step is to determine the pollution load on the air caused by pollution sources in the space. The total pollution load is found by adding the loads caused by the building and by the occupants. The available outdoor air quality and the ventilation effectiveness of the ventilated space are also considered. The ventilation rate required to provide the desired indoor air quality is then calculated based on the total pollution load, the available outdoor air quality and the ventilation effectiveness. The ventilation rates required for health and comfort are calculated separately and the highest value is used for design. | |
| 650 | 0 | |a Indoor air pollution. | |
| 650 | 0 | |a Ventilation. | |
| 650 | 0 | |a Indoor air pollution |x Health aspects. | |
| 650 | 0 | |a Ventilation |x Health aspects. | |
| 650 | 0 | |a Air conditioning |x Health aspects. | |
| 700 | 1 | |a Bienfait, Dominique. | |
| 710 | 2 | |a Commission of the European Communities. |b Joint Research Centre. |b Environment Institute. | |
| 710 | 2 | |a European Concerted Action : Indoor Air Quality & Its Impact On Man. | |
| 852 | 8 | |b CARM |i F11036 |p 0543188 |j no.11 |f BK | |
| 852 | 8 | |b SCAN |h A3:AK17C0 |i F11036 |p 0543188 |f BK | |
| 852 | 8 | |b SCAN |h A3:AK17C0 |i F11036 |p 0543188 |f BK | |
| 830 | 0 | |a Environment and quality of life ; |v no. 11. | |
| 830 | 0 | |a EUR (Series) ; |v 14449 EN. | |
| 999 | f | f | |i ae29988c-63af-5fdf-ae0a-1b1ea3467086 |s 1f64c18f-ae10-5aad-abfd-8e6840f63986 |
| 952 | f | f | |p Can circulate |a CAVAL |b CAVAL |c CAVAL |d CARM 1 Store |e F11036 |h Other scheme |i book |j no.11 |m 0543188 |
| 952 | f | f | |a CAVAL |b CAVAL |c CAVAL |d Unmapped Location |e F11036 |f A3:AK17C0 |h Other scheme |